Product
Description
The ASR series Storage server balances what the End-User and System vendor needs to deliver the best solution, provides classy design, highest flexibility, easy to iit nstall and maintain, more storage in limited space and ultimate drive and data protection in this limited space.
The ASR -212 has up to six hot-swappable cooling fans with multiple temperature sensors at the hot points that have been tested and approved by intel to support Nocona/Irwindale Processor up to 3.6Ghz.
The ASR -212 redundant load-sharing power supply modules and power management circuitry accommodate the dynamic requirements of today’s drives.
ASR -212 also includes power supply-to-drive isolation, which allows control over voltage and current fluctuations
Features and Benefits
- Supports SSI EEB 3.5, CEB 1.1 or AMD Dual Opteron compliant server boards
- Power MOSFET and pre-charge circuit for surge current protection on hard drive and backplane
- Horizontal backplane design to allow maximum airflow for system cooling
- Included SGS approved slide rail
- 3 years warranty on power supply
- Other High Quality Components are backed by life time warranty
Specification
| Dimensions |
3.5"(H) x 19"(W) x 28"(D) |
| Front Access Connector |
|
| Front Access switch |
ower On/Off, Reset, Alarm Reset |
| Front Panel Indicators |
Power On, HDD Activity, PSU failure, Fan failure, Over heat warning, LANs |
| Hot swap drive indicators |
Power On, HDD Activity, HDD failure |
| Power Supply |
550W 1+1 Hot-swap redundant power suppl |
| Power Supply Options |
460W Fixed, 600W Fixed |
| System Board |
Up to 12x13 E-ATX, ATX, EEB 3.5, CEB 1.1 compliant |
| Drive Bay |
Internal slim 2.5" x 1 ( 4 maximum ) |
Hotswap Bay x 12 |
|
| Data Backplane |
| Serial ATA PTP |
| Serial ATA Multilane |
| Ultra 320 SCA |
| Serial Attached SCSI |
|
| Included Data cable |
Yes |
| Included slide rail |
Yes |
| System Monitoring |
Fan / over heat / power supply fault detection |
| Thermal |
Intel Validated Pass Xeon 3.6Ghz 800Mhz |
SATA backplane Specification
- A power MOSFET to provide disk spin-up control
- A pre-charge circuit for surge current protection when a disk is plugged in to protect the hard-disk drive and the backplane.
- LED: Blue ON = HDD present; Blue Blanking = Drive activity; Red=Drive failed
- A 4x2 header for Drive activity and Drive failed LED signal input
- A 4x3 jumper with 4 jumper cap is added to select either disk activity LED is provide by the Host Bus Adapter or form HDD such as Western Digital or axtor Diamond Max X hard disk drive
- Single DC input to provide better cable management
- SATA data connector with latch to secure the SATA cable is not loose
- Options included Point-to-Point or Multilane data cable connection. 32pin 4-lane-to-1-lane connection available (special order only)
SCSI backplane Specification
- A power MOSFET to provide disk spin-up control
- A pre-charge circuit for surge current protection when a disk is plugged in to protect the hard-disk drive and the backplane.
- LED: Blue ON = HDD present; Blue Blanking = Drive activity; Red=Drive failed
- A 4x2 header for Drive activity and Drive failed LED signal input
- Single DC input to provide better cable management
- Piano Switch for easy SCSI ID setting
- Two HD68 SCSI connectors for daisy chain if required
Technical Documentation
| Technical Brochure |
ASR -212.pdf |
| User Manual |
ASR -212_manual_rev_1.pdf |
|